Search Catalog
        
 All Products    Fatigue Rated Universal Load Cells
All Products > Load Cells > Fatigue Rated Universal Load Cells > Item # FFL(4.5/±3)U(C)-(3/±2)  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Item # FFL(4.5/±3)U(C)-(3/±2), Fatigue Rated Universal Load Cells







Features  · Dimensional Drawing  · Specifications  · Performance Specs  · Electrical Specifications  · General Information

Features
  • Low Profile, Rugged, Compact & Lightweight
  • Low Deflection
  • High Frequency Dynamic Load Sensing
  • Pressure Compensating
  • Sealed Strain Gages
  • Counterbored Mounting Holes
  • Low Sensitivity to Extraneous Loads
  • High Static Overload
  • Highest Fatigue Rating in the Industry –One Billion Fully Reversed Cycles (Fatigue Rated Models)




Dimensional Drawing

Dimensional Drawing



Specifications

Load Capacity1

±3, C/R KIPS
4.5, U/D
KIPS

Type of Flat Load Cells

Fatigue Rated

Rated Output

2-mV/V C/R (Nominal)
2-mV/V C/R (Std. Output)

3-mV/V U/D (Nominal)

3-mV/V U/D (Std. Output)

Configuration

Dual Bridge
Single Bridge

Non-Linearity

General Purpose ±0.25% F.S.
Precision ±0.10% F.S.

Connector Type

Connector
Permanently Attached Cable

Hole Type

Threaded Loading Hole
Thru Hole

A - Diameter

11/16 in

B - Diameter

1-11/16 in

C - Diameter

3-3/16 in

D - Diameter

3-7/16 in

E - Length

4-15/32 in

F - Height

15/16 in

G - Width

2-15/16 in

H - Height

1 in

K - Outside Diameter

13/32 in

k - Inside Diameter

9/32 in

Number of Hold Down Bolt Holes

8

L - Diameter

2-7/16 in

M - Length

1/32 in

N - Depth of Hole

3/8 in

T - Hole

7/16-20UNF-2B
Thru Hole, 15/32"

Lifting Holes - Threads

NONE

Lifting Holes - BC. Diameter2

NONE

Basic Model

FL10U-2(Mod)

Weight

1.7 lb
1 U/D: Uni-directional load rating, from zero to maximum specified. C/R: Completely reversed load rating, plus and minus specified.
2 Bolt Circle Diameter


Performance Specs

Fatique Life

One Billion (109) Cycles

Bridge Resistance

350 Ohms (Nominal)

Excitation Voltage

15V AC or DC (Maximum)

Compensated Range

60 to 150 ºF

Temperature Effect on Bridge Balance

±0.0035% FS/°F

Temperature Effect on Output Signal

±0.0030% Load/°F (Nominal)

Non-Repeatability

±0.05% FS

Non-Linearity 

±0.25% FS

Hysteresis

±0.15% FS

Bridge Balance

±2% FS

Insulation Resistance

10,000 Megaohms (Minimum)


Electrical Specifications

Receptacle

PT02H-10-6P

Mating Plug

PT06A-10-6S (SR)

     Function

Pin

     (+) Excitation

A

     (-) Excitation

D

     (+) Signal

B

     (-) Signal

C

Cable

#20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)

     Function 

Wire Code

     (+) Excitation 

Red

     (-) Excitation 

Black

     (+) Signal 

Green

     (-) Signal 

White


General Information
Load Cells are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960. 

The structure is simple and compact, consisting of an inner loading hub and an outer supporting flange bridged smoothly by a uniformly continuous solid shear web avoiding structural stress risers.

Strain gages are installed and sealed inside small gage holes along the neutral axis of the web. Linearity and symmetry of output signal in tension and compression are obtained by equal straining of all shear gages in the bridge circuit.

Low deflection and high natural frequency are obtained, along with high resistance to extraneous forces. Mechanical and dynamic properties are fully tabulated.



 MORE IMAGES 

·  Limit Chart

·  Load Cell Cross Section

·  Universal Flat Load Cells - Dimension Drawing


 DOWNLOADS 

Fatigue Rated Load Cell Ordering Information
(PDF, 297KB)

Technical Information
(PDF, 210KB)

Fatigue Additional Information
(PDF, 79KB)

Spacers for Flat Load Cells
(PDF, 480KB)

Hold-Down and Loading Bolt Preload Torque Values
(PDF, 320KB)

Installation Instructions
(PDF, 558KB)

Strainsert Force Calibration Service
(PDF, 407KB)



 Renewal Parts 


page100
Standard Cable


PT1H-10-6P
PT1H-10-6P
Transducer Receptacles

more available ..