Strainsert
An AS9100C (Including ISO 9001:2008)
Certified Company
Call Now: 610-825-3310
Home
Products
Custom Solutions
Services
Applications
About Us
Catalog & CAD Library
Contact Us
Catalog Quick Links:
Load Pins
Load Cells
Custom Solutions
Force Sensing Bolts/Studs
Force Sensing Tension Links
Instruments
Accessories
Search Catalog
By Keyword
By Item #
All Products
Metric Universal Load Cells
All Products
>
Load Cells
>
Metric Universal Load Cells
>
Item # FL05UM
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # FL05UM, Metric Universal Load Cells
larger image
Features
·
Dimensional Drawing
·
Specifications
·
Performance Specs
·
Electrical Specifications
·
General Information
Features
Low Profile, Rugged, Compact & Lightweight
Low Deflection
High Frequency Dynamic Load Sensing
Pressure Compensating
Sealed Strain Gages
Counterbored Mounting Holes
Low Sensitivity to Extraneous Loads
High Static Overload
Dimensional Drawing
Dimensional Drawing
Metric Universal Load Cell
larger image
larger image
Specifications
Load Capacity
2.2
kN
Type of Flat Load Cells
Universal Metric
Rated Output
2-mV/V (Nominal)
2-mV/V (Std. Output)
Configuration
Single Bridge
Non-Linearity
General Purpose ±0.25% F.S.
Precision ±0.15% F.S.
Connector Type
Connector
Permanently Attached Cable
Hole Type
Threaded Loading Hole
Thru Hole
A - Diameter
17.5
mm
B - Diameter
36.5
mm
C - Diameter
63.5
mm
D - Diameter
66.7
mm
E - Length
93.7
mm
F - Height
23.8
mm
G - Width
71.4
mm
H - Height
25.4
mm
K - Outside Diameter
8.73
mm
k - Inside Diameter
5.56
mm
Number of Hold Down Bolt Holes
8
L - Diameter
49.2
mm
M - Length
0.8
mm
N - Depth of Hole
7.9
mm
T - Hole
10.53 -0/+0.02 Thru Hole
M10x1.5
Lifting Holes - Threads
NONE
Lifting Holes - BC. Diameter
NONE
Weight
0.3
kg
Material of Construction
Aluminum Alloy
Performance Specs
Accuracy
 
Non-Linearity
General Purpose ±0.25% FS
Precision ±0.15% FS
Hysteresis
General Purpose ±0.20% FS
Precision ±0.15% FS
Non-Repeatability
±0.05% FS
Environmental
 
Compensated Range
60 to 150
ºF
Effect on Zero
±0.0035% FS/°F
Effect on Output
±0.0030% Load/°F (Nominal)
Electrical
 
Excitation Voltage
15V AC or DC (Maximum)
Bridge Resistance
350 Ohms (Nominal)
Zero Balance
1
±2% FS (Nominal)
Insulation Resistance
10,000 Megaohms (Minimum)
Mechanical
 
Safe Static Overload without Zero Shift
200%FS
Safe Static Overload without Output Shift
200%FS
Safe Static Overload without Structural Failure
250%FS
1
Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.
Electrical Specifications
Mating Plug
PT06A-10-6S (SR)
Function
Pin
(+) Excitation
A
(-) Excitation
D
(+) Signal
B
(-) Signal
C
Cable
#20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)
Function
Wire Code
(+) Excitation
Red
(-) Excitation
Black
(+) Signal
Green
(-) Signal
White
General Information
Load Cells are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960.
The structure is simple and compact, consisting of an inner loading hub and an outer supporting flange bridged smoothly by a uniformly continuous solid shear web avoiding structural stress risers.
Strain gages are installed and sealed inside small gage holes along the neutral axis of the web. Linearity and symmetry of output signal in tension and compression are obtained by equal straining of all shear gages in the bridge circuit.
Low deflection and high natural frequency are obtained, along with high resistance to extraneous forces. Mechanical and dynamic properties are fully tabulated.
MORE IMAGES
·
Load Cell Cross Section
·
Universal Flat Load Cells - Dimension Drawing
DOWNLOADS
Metric Universal Load Cells Ordering Information
(PDF, 282KB)
Dimensions
(PDF, 113KB)
Technical Information
(PDF, 210KB)
Spacers for Flat Load Cells
(PDF, 480KB)
Installation Instructions
(PDF, 558KB)
Strainsert Force Calibration Service
(PDF, 407KB)
Hold-Down Bolt Preload Torque Values
(PDF, 46KB)
Renewal Parts
Standard Cable
PT1H-10-6P
Transducer Receptacles
more available ..