Item # FL300UM, Metric Universal Load Cells
larger image
Features
·
Dimensional Drawing
·
Specifications
·
Performance Specs
·
Electrical Specifications
·
General Information
Features
Low Profile, Rugged, Compact & Lightweight
Low Deflection
High Frequency Dynamic Load Sensing
Pressure Compensating
Sealed Strain Gages
Counterbored Mounting Holes
Low Sensitivity to Extraneous Loads
High Static Overload
Dimensional Drawing
Dimensional Drawing
Metric Universal Load Cell
larger image
larger image
Specifications
Load Capacity
1,335
kN
Type of Flat Load Cells
Universal Metric
Rated Output
2-mV/V (Nominal)
2-mV/V (Std. Output)
3-mV/V (Nominal)
3-mV/V (Std. Output)
Configuration
Dual Bridge
Single Bridge
Non-Linearity
General Purpose ±0.25% F.S.
Precision ±0.10% F.S.
Connector Type
Connector
Permanently Attached Cable
Hole Type
Threaded Loading Hole
Thru Hole
A - Diameter
127
mm
B - Diameter
235
mm
C - Diameter
368
mm
D - Diameter
381
mm
E - Length
419
mm
F - Height
38.1
mm
G - Width
95.3
mm
H - Height
102
mm
K - Outside Diameter
39.69
mm
k - Inside Diameter
26.99
mm
Number of Hold Down Bolt Holes
16
L - Diameter
299
mm
M - Length
17.5
mm
N - Depth of Hole
31.8
mm
T - Hole
76.55 -0/+0.05 Thru Hole
M76x2
Lifting Holes - Threads
M10
Lifting Holes - BC. Diameter
104.8
mm
Weight
78
kg
Material of Construction
Alloy Steel
Performance Specs
Accuracy
 
Non-Linearity
General Purpose ±0.25% FS
Precision ±0.10% FS
Hysteresis
General Purpose ±0.15% FS
Precision ±0.10% FS
Non-Repeatability
±0.05% FS
Environmental
 
Compensated Range
60 to 150
ºF
Effect on Zero
±0.0035% FS/°F
Effect on Output
±0.0030% Load/°F (Nominal)
Electrical
 
Excitation Voltage
15V AC or DC (Maximum)
Bridge Resistance
350 Ohms (Nominal)
Zero Balance
1
±2% FS (Nominal)
Insulation Resistance
10,000 Megaohms (Minimum)
Mechanical
 
Safe Static Overload without Zero Shift
200%FS
Safe Static Overload without Output Shift
200%FS
Safe Static Overload without Structural Failure
250%FS
1
Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.
Electrical Specifications
Mating Plug
PT06A-10-6S (SR)
Function
Pin
(+) Excitation
A
(-) Excitation
D
(+) Signal
B
(-) Signal
C
Cable
#20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)
Function
Wire Code
(+) Excitation
Red
(-) Excitation
Black
(+) Signal
Green
(-) Signal
White
General Information
Load Cells are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960.
The structure is simple and compact, consisting of an inner loading hub and an outer supporting flange bridged smoothly by a uniformly continuous solid shear web avoiding structural stress risers.
Strain gages are installed and sealed inside small gage holes along the neutral axis of the web. Linearity and symmetry of output signal in tension and compression are obtained by equal straining of all shear gages in the bridge circuit.
Low deflection and high natural frequency are obtained, along with high resistance to extraneous forces. Mechanical and dynamic properties are fully tabulated.
MORE IMAGES
·
Load Cell Cross Section
·
Universal Flat Load Cells - Dimension Drawing
DOWNLOADS
Metric Universal Load Cells Ordering Information
(PDF, 282KB)
Dimensions
(PDF, 113KB)
Technical Information
(PDF, 210KB)
Spacers for Flat Load Cells
(PDF, 480KB)
Installation Instructions
(PDF, 558KB)
Strainsert Force Calibration Service
(PDF, 407KB)
Hold-Down Bolt Preload Torque Values
(PDF, 46KB)
Renewal Parts
Standard Cable
PT1H-10-6P
Transducer Receptacles
more available ..