Bridge Measurement
|
|
4-wire
|
|
|
Bridge Excitation Voltage
|
|
4.5 to 5.25 (5 typical) VDC
|
|
|
Bridge Resistance
|
|
85 to 5000 (350, typical) Ohms
|
|
|
Bridge Sensitivity
|
|
-3 to 3 (2.5, typical) mV/V
|
|
|
Stability with Temperature, Offset
|
|
1 to 4 ppm/°C (0.6 to 2.2 ppm/°F)
|
|
|
Stability with Temperature, Gain
|
|
3 to 5 ppm/°C (1.7 to 2.8 ppm/°F)
|
|
|
Stability with Time, Offset
|
|
80, maximum (20, typical) ppm/F.R
|
|
|
Stability with Time, Gain
|
|
30, maximum (first year) ppm/F.R
|
|
|
Non-Linearity before Linearization
|
|
25, maximum (5, typical) ppm/F.R.
|
|
|
Internal Resolution
|
|
16 Million
|
|
|
Noise Free where Sample Time < 10ms
|
|
50,000 counts / divisions
|
|
|
Noise Free where Sample Time < 50ms
|
|
65,000 counts / divisions
|
|
|
Noise Free where Sample Time < 100ms
|
|
150,000 counts / divisions
|
|
|
Noise Free where Sample Time < 1000ms
|
|
250,000 counts / divisions
|
|
|
Noise Free where Sample Time > 1000ms
|
|
400,000 counts/divisions
|
|
|
Standby/Low Power Mode
|
|
20, maximum (5, typical) µA
|
|
|
Power Supply ripple
|
|
50, maximum mVAC PK-to-PK
|
|
|
Power Supply voltage
|
|
2.1 to 3.6 (3, recommended) and 5 to 18 (T24-ACM on optional external power) VDC
|
|
|
Power Supply current
|
|
65, maximum (60, typical max. with 1000 Ohm Bridge) mA
|
|
|
Battery Life expectancy, 2 AA cells (Low power mode. 3 Hz transmission rate. 350 Ohm Bridge.)
|
|
3 (Constantly on) weeks / 2 (12 sessions/day at 5 minutes per session) years
|
|