Strainsert Co.
12 Union Hill Rd.,West Conshohocken, PA 19428
Phone: 610-825-3310
Fax: 610-825-1734
Toll-free: 800-529-1502
Email: tfoley@strainsert.com
Website: http://www.strainsert.com
All Products > Tension Links > TLS, TLN and TLNS Series, Force Sensing Tension Links with Threaded Ends > Item # TLS-25 SS  


Item # TLS-25 SS, TLS - External Threads both Ends






Specifications  · Performance Specs  · Electrical Specifications  · General Information

Specifications

Dimensional Drawing

Load Capacity

25 KIPS

Material

Stainless Steel 17-4, H-1025 (Standard)

Connector Type

Connector
Permanently Attached Cable

AS - Length

1-1/2 in

B - Width

1-7/16 in

C - Diameter

2 in

D - Diameter

0.875 in

E - Length

1-5/8 in

F - Length

3/4 in

G - Length

1-7/8 in

L - Overall Length

7-1/4 in

R - Radius

3/8 in

T - Thread Size

1-8NC

Weight

3.1 lb

Safety Factor

2.3


Performance Specs

Overload without Zero Shift

150%

Bridge

Full bridge 350 Ohm (Nominal)

Excitation

12 V AC (Maximum)
12 V DC (Maximum)

Output Signal1

2-mV/V (Nominal)
2-mV/V (Standardized Output)

Non-Repeatability

0.10% FS

Non-Linearity

0.25% FS

Hysteresis

±0.15% FS

Temp Effects (on Zero)

0.003% FS / °F (Nominal)

Temp Effects (on Output)

0.003% load / °F (Nominal)

Zero Balance2

±2% FS (Nominal)

Static Overload

150% without zero or open shift
1 Exact output provided with calibration data. (Standardized outputs are optional).
2 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.


Electrical Specifications

Receptacle

PT02H-10-6P

Mating Plug

PT06A-10-6S (SR)

     Function

Pin

     (+) Excitation

A

     (-) Excitation

D

     (+) Signal

B

     (-) Signal

C

Cable

#20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)

     Function 

Wire Code

     (+) Excitation 

Red

     (-) Excitation 

Black

     (+) Signal 

Green

     (-) Signal 

White


General Information
Strainsert Tension Links are superior performance sensors, for use in weighing and force measuring applications.

Its sensing element consists of a strain gage bridge circuit internally installed in a small hole along its longitudinal axis. This unique arrangement provides a most effective means for the protection and sealing of the strain gage circuit while minimizing the adverse effects of extraneous torsional and flexural loads.

Tension Links can be modified for underwater use.