Search Catalog
        
 All Products    Analog 4 to 20 mA Strain Gage Module
All Products > Load Pins > Custom Load Pins > Load Pin Optional Features > Analog 4 to 20 mA Strain Gage Module  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Analog 4 to 20 mA Strain Gage Module



The Strainsert 2-wire Loop Powered 4 to 20 mA Strain Gage Modules are specially designed compact, high performance strain gage analog signal conditioner modules. They are aimed at 350 Ohm sensor applications which require high measurement accuracy, resolution, and stability. The internal signal conditioner reduces interference in noisy environments and allows for longer cable runs. The module and sensor may be powered by a typical DC power supply. Outputs may be configured for either UniPolar or Bi-Polar operation.

The modules may be mounted inside of the Strainsert sensor body in either a single bridge, dual bridge, or biaxial configuration.

Contact Strainsert Engineering for assistance with custom solutions, systems integration, or software development.





Features & Benefits  · Applications  · Specifications

Features & Benefits
Converts Bridge sensor output into 4 to 20 mA current loop.
Eliminates the need for external signal conditioner and interconnections.
Miniature package that fits into sensor body.
Ideal for single or multiple sensor systems
.



Applications
Aerospace
Industrial Weighing
Marine
Automotive




Specifications

Current Loop Supply

Min: 7.5 Volts
Typical: 24 Volts
Max: 36 Volts

Reverse Voltage Protection

Min: -100 Volts

Operating Current

Min: 3 mA
Typical: 4-20 mA
Max: 28 mA

Operating Temperature

Min: -40 °F
Max: 185 °F

Storage Temperature

Min: -67°F
Max: 257°F

Bridge Resistance

Typical: 350 Ohns

Bridge Excitation

Min: .730 Volts
Typical: .733 Volts
Max: .740 Volts

Bridge Sensitivity

Min: 0.5 mV/V
Typical: 2.0 mV/V
Max: 6.0 mV/V

Bandwidth

Min: 0 Hz
Max: 235 Hz

Zero-Scale Temperature Stability

Max: 0.0100 %FS/°F

Full-Scale Temperature Stability

Max: 0.0150 %FS/°F

Electrical Isolation

Min: 10^10 Ohms at 50 VDC



 DOWNLOADS 

4-20 mA Strain Gage Module
(PDF, 173KB)