Dual Bridge
larger image
Dual Bridge Clevis Pins provide two independent strain gage circuits. Dual Bridge transducers may use both bridges for simultaneous control and measurement or use a single bridge for measurement with the other bridge reserved as a spare.
Electrical terminations can be radial or axial using either single or dual connectors (dual shown below). Permanently attached cables can also be provided
Specifications
Bridge Composition
Full
Bridge Excitation
10 (typical), 12 maximum
Vdc
Bridge Resistance
350 (nominal)
Ohm
Bridge Sensitivity
0.5 and higher
mV/V
Temperature, Zero Load
0.01% (nominal) ±F.S./°F
Temperature, F.S. Load
0.01% (nominal) load/°F
Zero Balance
3.0% (nominal) ±F.S.
Non-Repeatability
0.25% (nominal) ±F.S.
Non-Linearity
1 % (nominal) ±F.S.
Hysteresis
1 % (nominal) ±F.S.
Safe Overload
150% (typical) ±F.S.
Ultimate Strength
300% (typical) ±F.S.
Minimum Pin Diameter
1 (standard), 0.5 (with limitations) inch
Material
17-4 Stainless Steel (typical)
Dual Bridge Wiring Diagram
dual-bridge-wiring-diagram
DOWNLOADS
Dual Bridge Load Pin Application Note
(PDF, 112KB)