Item # CBA-0.5-1, Load Bolts
Features
·
Dimensional Drawing
·
Performance Specs
·
Specifications
·
Electrical Specifications
·
General Information
Features
Precison Load Sensing
Rugged
Internally Sealed Strain Gages
Easy Installation
Direct Force Measurement
High Strength Stainless Steel
Dimensional Drawing
Dimensional Drawing
Load Pin
larger image
larger image
Performance Specs
Overload without Zero Shift
150%
Overload without Failure
300% (Minimum)
Bridge
Full bridge 350 Ohm (Nominal)
Excitation
12 V AC (Maximum)
12 V DC (Maximum)
Output Signal
1
2-mV/V (Nominal)
2-mV/V (Standardized Output)
Non-Repeatability
±0.15% FS (Nominal)
Non-Linearity
±0.50% FS (Nominal)
Hysteresis
±0.50% FS (Nominal)
Service Temp Range
to 150 °F
Temp Effects (on Zero)
0.005% FS / °F (Nominal)
Temp Effects (on Output)
0.008% load / °F (Nominal)
Zero Balance
2
±2% FS (Nominal)
1
Exact output provided with calibration data. (Standardized outputs are optional). In addition, Strainsert factory calibrations are intended to simulate installed conditions, however, it is recommended that an in-place calibration be performed to account for any installation, tolerance, and/or alignment influences affecting sensor measurement.
2
Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.
Specifications
Load Capacity
3,000
lb
Material
Stainless Steel 17-4, H-1025 (Standard)
A - Width of Center Loading Section
1/2
in
B - Width of Clevis Support Section
3/8
in
C - Length of Pin/Bolt Reduced Section, Instrumented Zone
1/4
in
Dp - Nominal Pin Diameter
0.500
in
E - Active Length of Pin
1-3/4
in
F - Clevis Pin Head Length
2
in
H - Width of Keeper Plate Slot
13/64
in
J - Depth of Keeper Plate Slot
1/4
in
L
B
- Overall Length of Bolt
4-1/4
in
X - Thread Length
1/2
in
Z - Thread Size
3/8-24UNF
Keeper Plates
SPA-12.5-112-1-A
Connector Type
Axial Connector
Permanently Attached Axial Cable
Electrical Specifications
Receptacle
PTIH-10-6P
Mating Plug
PT06A-10-6S (SR)
Function
Pin
(+) Excitation
A
(-) Excitation
D
(+) Signal
B
(-) Signal
C
Cable
#20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)
Function
Wire Code
(+) Excitation
Red
(-) Excitation
Black
(+) Signal
Green
(-) Signal
White
General Information
Clevis Load Pins are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960. We offer precision force measurement by simply replacing existing clevis pins.
The design is a double-shear arrangement. Typically, force P is applied at the center of the pin while 2 equal opposing forces of P/2 are applied at each end. Strain gages are sealed inside a small axial hole and are positioned at the 2 shear locations at the interface between the center eye and clevis ends. The strain gages are positioned and oriented with great precision along the neutral plane relative to the specific direction of force.
An anti-rotation device is necessary for proper reading and alignment. If a force P is applied to the pin at an angle other than the specified direction, the theoretical bridge output will be offset by a component of the force along the sensitive direction, i.e. P cos X.
The four strain gages (two at each shear location) are electrically connected to form a full bridge, the signal from each gage being additive so that the bridge output is proportional to the sum of the forces transmitted by the shear planes of the pin. The circuit typically includes temperature compensation, signal trim (optional), and zero balance resistors terminating in a suitable connector socket or integral cable, and potted with a sealing compound inside the gage hole for enhanced environmental protection.
Standard models include detailed calibration data up to 500,000 lbs. Higher capacity calibration data is available at an additional charge. Strainsert factory calibrations are intended to simulate installed conditions, however, it is recommended that an in-place calibration be performed to account for any installation, tolerance, and/or alignment influences affecting sensor measurement.
Standard models are typically used in new applications where the designer can develop the specific load pin joint around the standard load pin dimensions, to optimize force measurement performance. In addition, the standard load pin may fit or can be incorporated through the use of bushings or modification of the assembly.
Calibration data up to 500,000 lbs. Higher capacity calibration data is available at an additional charge. Inquire for custom product ranges.
MORE IMAGES
·
Clevis Pin with Two Shear Planes
·
CPAdim_new
·
Force F Direction
DOWNLOADS
CPA-CBA Load Pin Ordering Information
(PDF, 173KB)
Load Pin Installation
(PDF, 614KB)
Strainsert Force Calibration Service
(PDF, 407KB)
Load Sensing Clevis Pin Quick Start Guide
(PDF, 229KB)
Renewal Parts
Standard Cable
PT1H-10-6P
Transducer Receptacles
more available ..
Accessories
SPA-12.5-112-1-A
Keeper Plate
3/8-24SS
Clevis Bolt Threaded Collar