Item # PLNX-4, Portable Battery Powered Load Indicator (3-1/2 Digit, Multi-Channel)



The PLNX- line of indicators are 1, 2, 3, and 4 channel versions with the same basic circuitry and performancefeatures as the Model PLN-D2. Additional features include different instrument cases, and switching provisionsfor one to four channels which accommodate up to four transducers.

Indication is direct. Resolution is from 1 pound to 1000 pounds, depending on full scale transducer capacity.Alternate display units are available.

Simple operation. For normal use only three controls are involved: Turn on the power switch, select the channel,set the no load balance or tare reading to zero, and begin reading applied loads.

A shunt calibration function provides a quick test of transducer and indicator integrity.

The readout system is fully contained in a rugged and durable aluminum alloy case.

Power is provided by a set of rechargeable batteries. Batteries and a recharger with a retractable 110 Vac or220 Vac power cord, as specified, are included within the housing. In multichannel units, excitation voltage ismaintained on all transducers independent of channel switching.

Battery power allows complete freedom of use, andprovides average of 5 – 10 hours continuous operation,depending on transducer resistance. A ratiometricmeasuring technique prevents degrading system accuracydue to battery decay.

A visual display (Flashing “:”) signals that rechargingis needed.

Recharging is accomplished by withdrawing the rechargecord from its sealed compartment and plugging into astandard 110 Vac or 220 Vac, 60 or 50 Hz wall receptacle.220 Vac applications will require plug adapters to befurnished locally by the customer. Batteries are completelyrecharged overnight and can be left “on charge” indefinitely.
Readings can be obtained while the batteries are“on charge”. The instrument is effectively usable on eitherbattery or line power.

Nickel Cadmium Batteries and Recharger included.
Transducer cable connector: PT06A-10-6P(SR)
Visual Display of Low Battery, Over Range, Polarity.

For Full configuration click Request Information button.






Specifications

Channel

Four Channel Indicators

Display

3-1/2 digit, one or two dummy 0’s optional.

Display Accuracy

±1 count

Display Size

1/2 inch Liquid Crystal Display

Zero Balance Range

±20% full scale (FS)

Calibration Check

Preset to approximately 80% F.S.

Case Size

6" x 6" x 9"

Weight

6 lb

Bridge Resistance

120 Ohm
350 Ohm