Item # SCD1/G12, SCD1 Series Signal Conditioners
larger image
Features
·
Specifications
Features
The Model SCD1 is a series of signal conditioners which provide bridge excitation, amplification, span and balance controls and a choice of ±10 Vdc and/or 4-20 ma outputs. Primary input power is available in 120 Vac or a variety of Vdc voltage levels.
The SCD1 can accommodate up to four channels with ±10 Vdc outputs or a maximum of 2 channels with 4-20 ma outputs.
Standard SCD1 models are packaged in a NEMA-12 rated cabinet (NEMA-4X packages are available).
Each input channel is connected via a six (6) pin receptacle (PT02A-10-6S)
All output signals are provided at a terminal strip inside the signal conditioner cabinet . Each output signal has an individual terminal connection and each signal shares a single common return.
Note: When ordering specify input sensitivity, and desired full scale output.
Specifications
Dimensional Drawing
Signal Conditioner
larger image
larger image
Channel
Two Channel Input / Output
Output
± 10 Vdc
Power Supply Voltage
24 Vdc
Sensitivity
0.5-mv/V (minimum)
Excitation
Output Voltage
5 VDC (±0.2%)
Output Current
100 mA (maximum)
Regulation
0.05% Line
0.05% Load
Temp. Coefficient
0.002% F.S. / Deg. F
Input
Bridge Type
120 Ohm
350 Ohm
Sensitivity (minimum)
0.5-mv/V (minimum)
Voltage Amplifier
Input Impedance
> 1 Megohm
Output Impedance
< 0.1 Ohms
Gain
Adjustment
± 5% F.S.
Stability
± 0.002% F.S. / Deg. F
Linearity
± 0.02% F.S.
Zero
Adjustment
± 10% F.S.
Stability
± 0.006% F.S. / Deg. F
Source Current
± 7.5 ma
Output
Voltage Output
± 10 Vdc at 7.5 ma
Current Output (4-20 ma Units Only)
4-20ma (500 Ohm Load Max.)
Protection
Voltage Output protected against continuous short to ground. Current Output protected against continuous short to common and + Vcc
Dynamic Response
Filter
5 Hz, 40 dB/Octave, L.P. Butterworth
Settling Time
< 500us to within ±0.1% of the final value
Slew Rate
0.55V/us
Power Input
AC Power (AC Units ONLY)
105 to 125
Vac
Frequency
50 to 440
Hz
Dimensions
6” (H) x 6” (W) x 4” (D)
Environmental
Operating Temp
-10 to 150 °F
Storage Temp
-65 to 200 °F
MORE IMAGES
·
Typical Connection Diagram
DOWNLOADS
Standard Wiring Diagrams
(PDF, 600KB)
SCD1 Ordering Information
(PDF, 102KB)